Davicom Expansion Modules

Login to view prices

The MEXM-1 allows you to add 24 metering inputs, 24 status inputs and 24 relay outputs to your Davicom unit whereas the MEXM-2 allows you to add 64 status inputs.

Clear
SKU: MEXM Categories: ,

Description

A MEXM-1 adds…

24

Metering Inputs

24

Status Inputs

24

Relay Outputs

… to any Davicom unit*

A MEXM-2 adds…

64

Status Inputs

… to any Davicom unit*

MEXM-1

Using 8 MEXM-1 units together has the power to add:
192 additional Metering inputs to your Davicom Cortex unit
192 additional Status inputs to your Davicom Cortex unit

192 additional Relay outputs to your Davicom Cortex unit

Please refer to the second and third tables for the relevant maximums with the DV-200 units.

For example, adding a single MEXM-1 to a Cortex 360 provides a total of 32 metering inputs, 40 status inputs, and 32 relay outputs. These extra I/O’s are directly integrated into the Cortex’s control structure, therefore taking full advantage of the unit’s powerful control, monitoring, and automation functions.

Maximum number of I/O’s by Davicom Cortex Series model when using multiple MEXM-1 units in TCP mode:*

Cortex 320
Cortex 360
Metering
Status
Relays
Metering
Status
Relays
Maximum
204
196
198
200
208
200

Maximum number of I/O’s by Davicom DV-200 model when using multiple MEXM-1 units in TCP mode:*

DV-MICRO
DV-MINI
Metering
Status
Relays
Metering
Status
Relays
Maximum
136
200*
80
136
208*
80
DV-208
DV-216
Metering
Status
Relays
Metering
Status
Relays
Maximum
136
208*
88
144
224*
104

For better control and faster response time, all the inputs and outputs of the MEXM-1 are scanned up to 10 times per second (10 Hz).

 

For use with a Cortex unit, we recommend that you download the latest firmware now.

For use with a DV-200 unit, firmware version 5.52 or later is required in your control unit.

Both files can be found here after creating an account on dex.davicom.com. A user account is required for downloads.

MEXM-2

Adding a single MEXM-2 with its 64 status inputs to a Cortex 360 yields a total of 80 Status inputs in a cost-effective package. These extra inputs are directly integrated into the Cortex’s control structure, therefore taking full advantage of the unit’s powerful control, monitoring, and automation functions. You may mix MEXM-2 units with MEXM-1 units in order to create the customized I/O solution that perfectly meets your project’s needs.

Maximum number of I/O’s by Davicom Cortex Series model when using MEXM-2 units with MEXM-1 units in TCP mode:*

Cortex 320
Cortex 360
Metering
Status
Relays
Metering
Status
Relays
Max. using
1 MEXM-2**
180
236
174
176
248
176
Max. using
2 MEXM-2s**
156
260
150
152
272
152

Maximum number of I/O’s by Davicom DV-200 model when using MEXM-2 units with MEXM-1 units in TCP mode:* **

DV-MICRO
DV-MINI
Metering
Status
Relays
Metering
Status
Relays
Maximum
136
264
80
136
272
80
DV-208
DV-216
Metering
Status
Relays
Metering
Status
Relays
Maximum
136
272
88
144
288
104

For better control and faster response time, all the inputs of the MEXM-2 are scanned up to 10 times per second (10 Hz).

 

For use with a Cortex unit, we recommend that you download the latest firmware now.

For use with a DV-200 unit, firmware version 5.52 or later is required in your control unit.

Both files can be found here after creating an account on dex.davicom.com. A user account is required for downloads.

* The maximum number of usable I/O’s from any MEXM combination is determined by a combination of Modbus protocol limitations, the Davicom unit firmware and the number of MEXM units used. In Modbus RTU mode, a total of 7 MEXM units can be used. Contact us to discuss your unique project needs.

 

** The I/O figures shown here are when MEXM-1 units are combined with MEXM-2 units for a total of 8 units.

Additional information

Weight N/A
Dimensions N/A
Version